Micropore structure
More than 95% micropore volume is listed, with pores under 2 nm, supporting adsorption of smaller organic molecules.
Coconut shell granular activated carbon for dissolved organics, colour, odour, chlorine, medication residues and other listed compounds in aquarium, aquaculture and water treatment systems.

Adjust within the range for bioload and water quality. Slower flow gives better adsorption.
More than 95% micropore volume is listed, with pores under 2 nm, supporting adsorption of smaller organic molecules.
The product specification lists 1100–1150 m²/g total surface area measured by the N₂ BET method.
At least 98% hardness and very low dust support cleaner handling and longer media-bed service between changes.
1100–1150 m²/g by N₂ BET method.
≥1050 mg/g per ASTM D4607.
55% per ASTM D3467.
≥98% per ASTM D3802.
0.45–0.5 cm³/g total pore volume, with more than 95% micropore volume.
≤8% ash and ≤5% moisture under the listed test methods.
Actual performance depends on concentration, contact time, flow, competing compounds and replacement schedule.
Tannins, humic acids, yellow water and other dissolved organic compounds.
Geosmin, 2-MIB and other taste or odour compounds listed for carbon adsorption.
Useful for treating source water and makeup water where these residuals are present.
Suitable for post-treatment cleanup when the treatment label permits activated carbon use.
Volatile organic compounds and phenolic compounds are included in the listed target group.
Pesticides, herbicides, hydrogen sulphide and mercaptans are listed application targets.
| Parameter | Value | Method or note |
|---|---|---|
| Aquarium dose (general) | 100–200 mL per 100 L | Adjust for bioload and water quality |
| Post-medication cleanup | 48–72 hours | Then remove; follow treatment instructions |
| Replacement interval | Every 4–8 weeks | Depends on bioload and water quality |
| Total surface area | 1100–1150 m²/g | N₂ BET |
| Iodine number | ≥1050 mg/g | ASTM D4607 |
| CTC activity | 55% | ASTM D3467 |
| Hardness | ≥98% | ASTM D3802 |
| Apparent density | ≥0.45 g/mL | ASTM D2854 |
| Ash content | ≤8% | ASTM D2866 |
| Moisture | ≤5% | ASTM D2867 |
| Total pore volume | 0.45–0.5 cm³/g | Typical value |
| Micropore volume | >95% | Sub-2 nm |
| Mesh size | 8×30 (0.6–2.3 mm) | Minimum 90% listed |
Use a 500 μm mesh or finer bag and rinse the carbon until the water runs clear.
The 8×30 granules can be used in a suitable fluidised reactor with controlled flow.
Suitable for a compatible pressurised filter housing sized for the system flow.
The label guidance places carbon downstream of biological filtration for best results.
Granular ferric hydroxide for phosphate, silicate and a range of heavy metals in aquarium and aquaculture systems.
View FERRIX-03Send BTA your system volume, application and current water-quality readings for a more sensible media recommendation.
Contact BTACoconut shell granular activated carbon supplied in the selected native Shopify variant.
General aquarium starting rate of 100–200 mL per 100 L, with replacement every 4–8 weeks.
Key surface-area, pore-volume, hardness, mesh and activity values are listed above.
For aquaculture, RAS and water-treatment systems, contact BTA with volume, flow, loading and current water-quality information.
Use CARBOX 830 for dissolved organic control and select a separate media when phosphate, silicate or metals are the primary concern.
The general aquarium starting rate is 100–200 mL per 100 L of system water. Adjust within that range for bioload and water quality, and contact BTA for aquaculture or RAS systems.
8×30 mesh, listed as 0.6–2.3 mm granule size. The supplied guidance identifies this range for media bags, reactors and filter housings.
The supplied product information lists dissolved organic compounds, taste and odour compounds, chlorine and chloramine, medication and antibiotic residues, VOCs and phenols, pesticides and herbicides, endocrine disruptors, hydrogen sulphide and mercaptans.
Yes. Use a 500 μm mesh or finer bag, a suitable fluidised reactor or a compatible pressurised filter housing. Rinse before loading.
The supplied label guidance is every 4–8 weeks depending on bioload and water quality. Higher-demand systems may require more frequent replacement.
Yes. Rinse thoroughly with fresh water until it runs clear before first use. Avoid inhaling dust.
Send BTA your system volume, application and current water-quality readings. We can help you choose a sensible starting point.