Sealless design
No mechanical seal means nothing to wear or leak. The impeller shaft is fully enclosed inside a sealed containment shell — no seal replacement, no seal leakage, no contamination path.
Sealless magnetic drive pumps — torque passes through a sealed containment shell, so there is no mechanical seal to wear, replace or leak. 18 models from 40W to 3700W in 220V single-phase and 380V three-phase.
No mechanical seal means nothing to wear or leak. The impeller shaft is fully enclosed inside a sealed containment shell — no seal replacement, no seal leakage, no contamination path.
Magnets transmit torque through the shell wall. The outer drive ring on the motor turns the inner impeller ring through the sealed barrier — zero physical contact, zero wear path.
6 single-phase and 12 three-phase models cover 35–900 L/min and heads to 29 m, with threaded connections on smaller models and flanges on industrial sizes.
Sealed containment shell isolates the fluid completely from the motor and the environment.
PP and GFRPP wetted parts handle salts, mild acids and a wide range of chemicals.
No seal friction — magnetic coupling runs smoother with less vibration.
Rated S1 for 24/7 operation in recirculation and life-support systems.
Close-coupled monoblock — no couplings, no alignment, no baseplate.
No seal servicing ever — the impeller is the only part to inspect.
35 to 900 L/min across 18 models — one range from small recirc to industrial flow.
BSP threaded and flanged options matched to model size.
| Model | Supplier code | Power | Voltage | Rated flow | Rated head | Inlet | Outlet |
|---|---|---|---|---|---|---|---|
| PMD-35 | MP-30 | 40W | 220V/50Hz | 35 L/min | 4 m | DN25 BSP | DN25 BSP |
| PMD-40 | MP-40 | 60W | 220V/50Hz | 43 L/min | 4.6 m | DN25 BSP | DN25 BSP |
| PMD-70 | MP-55 | 90W | 220V/50Hz | 74 L/min | 5.6 m | DN32 BSP | DN32 BSP |
| PMD-85 | MP-70 | 180W | 220V/50Hz | 85 L/min | 6.7 m | DN32 BSP | DN32 BSP |
| PMD-100 | MP-100 | 260W | 220V/50Hz | 100 L/min | 11 m | DN40 BSP | DN40 BSP |
| PMD-220 | MP-120 | 370W | 220V/50Hz | 220 L/min | 10.5 m | DN50 BSP | DN50 BSP |
| PMD3-130 | MPH-122H | 370W | 380V/50Hz | 130 L/min | 13 m | DN50 BSP | DN50 BSP |
| PMD3-160 | MPH-144 | 370W | 380V/50Hz | 160 L/min | 15 m | DN50 BSP | DN50 BSP |
| PMD3-240 | MPH-344 | 550W | 380V/50Hz | 240 L/min | 15 m | DN65 BSP | DN65 BSP |
| PMD3-350 | MPH-444 | 750W | 380V/50Hz | 350 L/min | 17 m | DN65 BSP | DN65 BSP |
| PMD3-400 | MPH-554 | 1500W | 380V/50Hz | 400 L/min | 23 m | DN80 flange | DN80 flange |
| PMD3-615 | MPH-565L | 1500W | 380V/50Hz | 615 L/min | 18 m | DN80 flange | DN80 flange |
| PMD3-500 | MPH-654 | 2200W | 380V/50Hz | 500 L/min | 25 m | DN80 flange | DN80 flange |
| PMD3-760 | MPH-665 | 2200W | 380V/50Hz | 760 L/min | 18 m | DN80 flange | DN80 flange |
| PMD3-500HD | MPH-754 | 3000W | 380V/50Hz | 500 L/min | 28 m | DN100 flange | DN100 flange |
| PMD3-750HD | MPH-765 | 3000W | 380V/50Hz | 750 L/min | 22 m | DN100 flange | DN100 flange |
| PMD3-600HD | MPH-854 | 3700W | 380V/50Hz | 600 L/min | 29 m | DN100 flange | DN100 flange |
| PMD3-900HD | MPH-865 | 3700W | 380V/50Hz | 900 L/min | 26 m | DN100 flange | DN100 flange |
| Model | Supplier code | L mm* | W mm* | H mm* | Weight kg* | Inlet | Outlet |
|---|---|---|---|---|---|---|---|
| PMD-35 | MP-30 | 180 | 120 | 130 | 2.5 | DN25 BSP | DN25 BSP |
| PMD-40 | MP-40 | 180 | 120 | 130 | 2.8 | DN25 BSP | DN25 BSP |
| PMD-70 | MP-55 | 200 | 130 | 140 | 3.5 | DN32 BSP | DN32 BSP |
| PMD-85 | MP-70 | 200 | 130 | 140 | 3.8 | DN32 BSP | DN32 BSP |
| PMD-100 | MP-100 | 230 | 150 | 160 | 5.2 | DN40 BSP | DN40 BSP |
| PMD-220 | MP-120 | 260 | 170 | 180 | 7.5 | DN50 BSP | DN50 BSP |
| PMD3-130 | MPH-122H | 280 | 180 | 190 | 9.0 | DN50 BSP | DN50 BSP |
| PMD3-160 | MPH-144 | 280 | 180 | 190 | 9.5 | DN50 BSP | DN50 BSP |
| PMD3-240 | MPH-344 | 310 | 200 | 210 | 12.0 | DN65 BSP | DN65 BSP |
| PMD3-350 | MPH-444 | 340 | 220 | 230 | 15.0 | DN65 BSP | DN65 BSP |
| PMD3-400 | MPH-554 | 380 | 250 | 260 | 20.0 | DN80 flange | DN80 flange |
| PMD3-615 | MPH-565L | 380 | 250 | 260 | 22.0 | DN80 flange | DN80 flange |
| PMD3-500 | MPH-654 | 400 | 270 | 280 | 25.0 | DN80 flange | DN80 flange |
| PMD3-760 | MPH-665 | 400 | 270 | 280 | 27.0 | DN80 flange | DN80 flange |
| PMD3-500HD | MPH-754 | 420 | 280 | 290 | 30.0 | DN100 flange | DN100 flange |
| PMD3-750HD | MPH-765 | 420 | 280 | 290 | 32.0 | DN100 flange | DN100 flange |
| PMD3-600HD | MPH-854 | 440 | 300 | 310 | 35.0 | DN100 flange | DN100 flange |
| PMD3-900HD | MPH-865 | 440 | 300 | 310 | 38.0 | DN100 flange | DN100 flange |
* Dimensions estimated — verify with supplier drawings before installation.
Chart labels use the same model codes as the tables above — match each curve directly to its row. (T) suffix denotes the three-phase variant of that frame.
DN25 · DN32 · DN40 · DN50 · DN65
DN80 · DN100
220V/50Hz single-phase (cable & plug) · 380V/50Hz three-phase (unwired)
PMD3-500HD → PMD3-900HD — heads to 29 m, DN100 flanges
Threaded adapters, unions, valves and hose tails to connect from pump to pipe. View plumbing fittings
Air pumps and diffusers to pair circulation with dissolved-oxygen management. View aeration range
PRIMUS flow and pressure runs nanobubble nozzles for advanced gas-transfer duty. View nanobubble nozzles
Complete magnetic drive pump with impeller and coupling assembly — arrives as one integrated unit, no assembly required.
220V models ship with cable and plug fitted. 380V models are unwired for hardwire connection by a qualified electrician.
Installation, operation and maintenance guide covering priming, pipe sizing and impeller inspection.
Step up as the system grows — single-phase PMD-35 → PMD-220, three-phase PMD3-130 → PMD3-760 — each step adds flow and head.
PMD3-500HD through PMD3-900HD deliver heads up to 29 m with DN100 flanged connections for high static-head industrial installs.
380V motors run cooler and deliver more torque per watt — the efficient choice for continuous commercial duty.
Need a custom configuration?
We can help match flow rate, head pressure and fluid compatibility to the right model.
Contact usA mag drive pump uses magnetic coupling to transmit torque from the motor to the impeller through a sealed containment shell. No mechanical seal means zero leakage — the fluid never contacts the motor.
220V single-phase models (PMD-35 to PMD-220) plug into a standard outlet — ideal for smaller systems. 380V three-phase models (PMD3-130 to PMD3-900HD) need a three-phase supply and are wired on-site — suited to commercial installations.
Models up to DN65 use BSP female thread for easy plumbing integration. DN80 and DN100 models use flange connections for secure industrial pipe mating.
No. The pump must be primed before operation — running dry can damage the impeller and magnetic coupling. Always ensure the pump is flooded before starting.
Yes. All PRIMUS mag drive pumps are rated S1 continuous duty — designed to run 24/7 without interruption.
Smaller models use PP (polypropylene); larger models use GFRPP (glass-filled polypropylene). Both handle a wide range of chemicals, salts and mild acids — check compatibility with your specific fluid before ordering.
Contact BTA Aqua for current warranty terms. We back every pump we sell with local support and spare parts availability.
With 18 models across two voltage ranges, we'll help you match flow rate, head pressure and connection type to your system.
Get in touch Browse all productsBulk pricing for commercial aquaculture operations, installers and resellers. Apply for a trade account for exclusive pricing and priority support.