SENECT| Replacement Electrodes & Spares
SENECT| Replacement Electrodes & Spares
SENECT Sensors
& SPARES
The complete range of SENECT water quality sensors, replacement electrodes, calibration standards, and spare parts — engineered in Germany for reliable, long-term aquaculture monitoring and control.
Sensors measure. Control units process. Actuators respond. SENECT develops and manufactures high-quality aquaculture technology in Landau, Germany. Their modular IoT system lets you build a complete farm monitoring solution — and every sensor on this page is Plug & Play compatible with all SENECT control units, from the SENECT|ONE to the AQUACULTURE|CONTROL. BTA is your Australian source for the full sensor range, replacement electrodes, calibration standards, and spare parts.
The Difference is in the Data
Optical, Not Electrochemical
The O2S dissolved oxygen sensor uses optical luminescence quenching — no electrolyte to refill, no membrane to replace, no flow dependency. Just accurate, drift-resistant readings for years, with a single cap swap when needed.
Inductive Conductivity
The CON sensor uses an inductive measurement principle — corrosion-free, nearly maintenance-free, and temperature-compensated. No electrodes in contact with water means no fouling, no drift, and reliable salinity calculations in both fresh and saltwater.
Serviceable by Design
pH and ORP electrodes use standard BNC connectors and can be replaced in minutes — no tools, no factory return. Calibration standards are available in 20 ml sachets. The O2S cap is a single push-fit replacement. Total cost of ownership stays low.
Built for the Field
IP68 submersible ratings on sensors, IP65 on alarm lamps, stainless steel 1.4435 / 1.4542 wetted parts, polypropylene housings, and cable lengths from 5 m to 10 m standard. Extension cables available for remote installations.
Integrated Ecosystem
Every sensor connects directly to any SENECT control unit via the standardised Plug & Play system. The SENECT Control App displays live readings, triggers alarms, and drives actuators — all from your smartphone, tablet, or PC over Wi-Fi.
Intelligent Control
Sensors don't just monitor — they drive automation. Oxygen readings trigger solenoid valves and oxygen generators. Temperature feeds feeding algorithms. Conductivity drives salinity calculations. Pressure sensors protect pipelines. Data becomes action.
Sensor & Spares Matrix
| Art. No. | Product | Category | Key Specs | IP | Cable |
|---|---|---|---|---|---|
| 2100 | Oxygen Sensor O2S | Sensor | 0–20 mg/L, optical, SS 1.4435, Ø12×94mm | IP68 | 7.5 m |
| 2101 | O2S — Sensor Cap | Spare | Exchange cap, ~2 yr or >1M measurements | — | — |
| 2102 | O2S — SS Holder | Accessory | Holder + hanger bolt for O2S sensor | — | — |
| 2103 | O2S — Protective Hood | Accessory | Protective hood for O2S sensor | — | — |
| 2200 | pH Sensor XR1 | Sensor | pH 4–10, replaceable electrode, indirect CO₂ | IP68/67 | 2+5 m |
| 2201 | pH Electrode XR1-AT | Spare | Replacement pH electrode, BNC connector | IP68 | — |
| 2209 | pH Calibration Set | Spare | pH 4.01 & 10.01 standards, 20 ml each | — | — |
| 2300 | ORP Sensor XT1 | Sensor | −1000 to +1000 mV, replaceable electrode | IP68/67 | 2+5 m |
| 2301 | ORP Electrode XT1-AT | Spare | Replacement ORP electrode, BNC connector | IP68 | — |
| 2309 | ORP Calibration Standard | Spare | +475 mV standard, 20 ml | — | — |
| 2410 | Conductivity Sensor CON-2 | Sensor | 0–2000 µS/cm, freshwater, inductive | IP68 | 10 m |
| 2400 | Conductivity Sensor CON-50 | Sensor | 0–50 mS/cm, saltwater, inductive | IP68 | 10 m |
| 2002 | Pressure Sensor EDS 2.5 bar | Sensor | 0–2500 mbar, piezoresistive, SS 1.4542 | IP65 | 5 m |
| 3450 | Extension Cable 5 m | Accessory | Extension cable with 2 plugs, 5 m | — | 5 m |
| 3460 | Extension Cable 10 m | Accessory | Extension cable with 2 plugs, 10 m | — | 10 m |
| 3200 | Alarm Lamp VIS-LED | Accessory | Visual LED alarm, Ø61.8×62.8mm, ABS | IP65 | 5 m |
| 3210 | Alarm Lamp VIS-LED AK | Accessory | LED lamp + horn, Ø90×97mm, ABS | IP65 | 5 m |
| 3100 | Power Switch SC24-230 | Accessory | 230V adapter, max 2000W, Schuko IP44 | IP44 | 1 m |
| 3020 | Solenoid Valve Oxygen M7 | Valve | Normally open, brass, G1/8", 0.2–7 bar | IP67 | 5 m |
| 3010 | Solenoid Valve Water M12 | Valve | Normally closed, brass, G1", 0.2–12 bar | IP67 | 5 m |
| 3301 | Fish Feeder 5L | Feeder | ~5 kg capacity, 2–9mm pellet, PVC/PP | IP44 | 5 m |
| 3302 | Hatchery Fry Feeder | Feeder | ~2L, powder feed ≤2mm, LED attract | IP54 | 5 m |
All sensors compatible with all SENECT control units. Spare parts in stock or available on order.
Each Sensor Explained
Oxygen Sensor O2S — Art. 2100
Optical dissolved oxygen sensor using luminescence quenching. Range 0–20 mg/L / 0–200% saturation. Accuracy <1% FS, T90 <30s. Stainless steel 1.4435 body, IP68. The only consumable is the exchangeable sensor cap (Art. 2101, ~2 yr life). Also available: stainless steel holder (Art. 2102) and protective hood (Art. 2103).
pH Sensor XR1 — Art. 2200
Electrochemical pH sensor, range pH 4–10, accuracy <±2% FS. UW-glass body with ceramic diaphragm. BNC connector for quick electrode swaps (Art. 2201). Unique feature: when paired with temperature and alkalinity data, SENECT controllers calculate dissolved CO₂ concentration — a powerful tool for aquaculture water quality management. Calibration set Art. 2209.
ORP Sensor XT1 — Art. 2300
Electrochemical REDOX sensor, range −1000 to +1000 mV, accuracy <±2.5% FS. Glass body with ceramic diaphragm, Pg13.5 thread. Ideal for denitrification filter control, ozone dosing verification, and water quality monitoring. Replacement electrode Art. 2301 (BNC). Calibration standard +475 mV: Art. 2309.
Conductivity Sensors CON — Art. 2410 / 2400
Inductive measurement — no electrodes, no corrosion, no fouling. CON-2 (Art. 2410): 0–2000 µS/cm for freshwater. CON-50 (Art. 2400): 0–50 mS/cm for saltwater/marine. Polypropylene housing, G1½" PVC process connection, integrated temperature sensor, IP68, 10 m cable. SENECT controllers auto-calculate salinity in PSU.
Pressure Sensor EDS — Art. 2002
Piezoresistive membrane sensor for gas and liquid media. Stainless steel 1.4542 wetted parts, G1/4" inner thread. Accuracy <0.5% FS. Ideal for monitoring aeration/oxygen pipelines and drum filter spray bars. Available in 2.5, 4, and 6 bar ranges. Extension cables: Art. 3450 (5 m), Art. 3460 (10 m).
Alarm Lamps VIS-LED — Art. 3200 / 3210
Long-lasting LED alarm indicators with IP65 rating for outdoor use. VIS-LED (Art. 3200): visual only, Ø62mm, −25 to +70°C. VIS-LED AK (Art. 3210): visual + acoustic horn with selectable tone and adjustable volume, Ø90mm. Both wall-mountable, 5 m cable, ~1.2W power draw. Connect to any SENECT actuator port.
Power Switch SC24-230 — Art. 3100
Switches 230V AC consumers (up to 2000W) via SENECT actuator output ports. Drive oxygen generators, pumps, and high-power equipment from any SENECT control unit. Schuko IP44 plugs, ASA housing, 1 m cables each side. Maximises AQUACULTURE|CONTROL functionality with up to 8 × 230V outputs.
Solenoid Valves — Art. 3020 / 3010
Oxygen M7 (Art. 3020): Normally open brass valve, G1/8", 0.2–7 bar. Oxygen flows during power failure — protecting your stock. Water M12 (Art. 3010): Normally closed brass valve, G1", 0.2–12 bar, up to 90°C. For auto-refill and water supply lines. Both IP67, 5 m cable, ~10W.
Fish Feeders — Art. 3301 / 3302
Fish Feeder 5L (Art. 3301): Rotor dispenser, 2–9mm pellets, ~5 kg capacity, wall-mount, IP44. Hatchery Fry Feeder (Art. 3302): For powder and fine feed (≤2mm), ~2L, moisture-sealed aperture, integrated LEDs to attract fish. Both 12V DC, <10W, 5 m cable, intelligent control via SENECT controllers with feed-to-temperature curves and oxygen-conditional feeding.
Sensor Specs Overview
Sensor Setup Guide
Plug Into Controller
Connect any SENECT sensor to any SENECT control unit — auto-detect handles configuration. No dip switches, no manual setup.
Open the App
The SENECT Control App displays live readings instantly on smartphone, tablet, or PC over Wi-Fi. No cloud dependency — runs on your local network.
Set Alarms & Actuators
Configure alarm thresholds and link sensors to solenoid valves, oxygen generators, pumps, or feeders. Data becomes action automatically.
Review & Export Data
All readings are logged. Export CSV data for analysis, compliance reporting, or integration with your farm management system. Data is king.
Frequently Asked Questions
Q Are SENECT sensors compatible with all SENECT control units?
Q How often does the O2S oxygen sensor cap need replacing?
Q Can I replace pH and ORP electrodes myself?
Q What's the difference between CON-2 and CON-50?
Q Does the pH sensor really measure CO₂?
Q Are extension cables available?
Q "Normally open" vs "normally closed" — what's the difference?
Q Does BTA carry stock in Australia?
We Get It, There's A Bit Here.
Figuring out the exact sensors, electrodes, and spares you need shouldn't be stressful. Give us a call, and we'll help you get exactly what you need — nothing you don't — saving you a good amount of stress and guesswork.
📞 Call Us For HelpOne ecosystem. Every measurement.
SENECT sensors are the eyes and ears of your aquaculture facility. From optical oxygen to inductive conductivity, every sensor is built for reliability, serviceability, and instant Plug & Play integration with the complete SENECT control ecosystem.