{"product_id":"uvonic-cmla-multi-lamp-amalgam-uv-steriliser","title":"UVONIC CMLA Multi-Lamp Amalgam UV Steriliser | BTA","description":"\u003cstyle\u003e\n@font-face{font-family:\"MBF-Humanica\";src:url(\"\/\/cdn.shopify.com\/s\/files\/1\/0731\/5200\/4338\/files\/MBF-Humanica.woff\") format(\"woff\");font-display:swap;font-style:normal;font-weight:400}\n.product__title,.product__info h1,.product__title h1{display:none!important}\n.bta-uvo-page{--coal:#EDF7F2;--dark:#E2F1EA;--panel:#D8ECDF;--card:#FFFFFF;--ink:#123326;--text:#1a2e24;--muted:#4a6b5c;--ocean-deep:#075985;--ocean-mid:#0369A1;--violet-deep:#4C1D95;--violet:#7C3AED;--violet-pale:#EDE9FE;--copper-deep:#78350f;--copper-bright:#B45309;--line:rgba(18,51,38,.14);--shadow:0 16px 44px rgba(18,51,38,.12);--radius:18px;background:var(--coal);color:var(--text);font-family:Inter,\"Segoe UI\",Arial,sans-serif;line-height:1.65;width:100vw;max-width:100vw;margin-left:calc(50% - 50vw);margin-right:calc(50% - 50vw);overflow:hidden}\n.bta-uvo-page *{box-sizing:border-box}\n.bta-uvo-page a{color:#0369A1;text-decoration:underline;text-underline-offset:3px}\n.bta-uvo-page a:hover{color:#075985}\n.bta-uvo-page a:focus-visible,.bta-uvo-page summary:focus-visible{outline:3px solid #7C3AED;outline-offset:4px;border-radius:4px}\n.bta-uvo-page h1,.bta-uvo-page h2,.bta-uvo-page h3,.bta-uvo-page h4{font-family:\"MBF-Humanica\",\"Arial Black\",Impact,sans-serif;color:#123326;line-height:1.05;margin:0 0 1rem}\n.bta-uvo-page h1{font-size:clamp(2.4rem,6vw,5rem);letter-spacing:-.035em;text-transform:uppercase}\n.bta-uvo-page h2{font-size:clamp(2rem,5vw,3.6rem);letter-spacing:-.02em}\n.bta-uvo-page h3{font-size:1.35rem}\n.bta-uvo-wrap{width:min(1360px,100%);margin:auto;padding:.25rem clamp(.75rem,4vw,3.5rem)}\n.uv-kicker{display:inline-flex;border:1px solid rgba(3,105,161,.28);padding:.45rem .8rem;margin-bottom:.75rem;color:#0369A1;font-family:\"MBF-Humanica\",\"Arial Black\",Impact,sans-serif;font-size:.72rem;font-weight:bold;letter-spacing:.28em;text-transform:uppercase;border-radius:.25rem}\n.uv-lead{font-size:clamp(1rem,2vw,1.25rem);color:#4a6b5c;max-width:42rem;margin:0 0 1.75rem}\n.uv-stat-row{display:flex;flex-wrap:wrap;gap:.7rem;margin:0 0 1.6rem}\n.uv-stat{display:flex;align-items:center;gap:.55rem;background:#FFFFFF;border:1px solid var(--line);border-radius:999px;padding:.65rem 1rem;box-shadow:0 5px 16px rgba(18,51,38,.06)}\n.uv-stat strong{font-family:\"MBF-Humanica\",\"Arial Black\",Impact,sans-serif;font-size:1.5rem;color:#075985;line-height:1}\n.uv-stat small{color:#4a6b5c;font-size:.72rem;letter-spacing:.08em;text-transform:uppercase}\n.uv-hero{position:relative;background:linear-gradient(135deg,#EDF7F2,#f7fcf9 55%,#D8ECDF);padding:clamp(4rem,10vw,8rem) 0 5rem;overflow:hidden}\n.uv-hero:before{content:\"\";position:absolute;width:45rem;height:45rem;border-radius:50%;right:-14rem;top:-12rem;border:1px solid rgba(3,105,161,.15);box-shadow:0 0 0 4rem rgba(3,105,161,.035),0 0 0 9rem rgba(124,58,237,.025);pointer-events:none}\n.uv-hero-grid{display:grid;grid-template-columns:minmax(0,1.05fr) minmax(280px,.95fr);gap:clamp(2rem,6vw,6rem);align-items:center}\n.uv-hero h1 span{color:#0369A1}\n.uv-hero-media{position:relative;display:flex;justify-content:center;align-items:center;min-height:25rem}\n.uv-hero-media:before{content:\"\";position:absolute;inset:8%;border-radius:50%;background:radial-gradient(circle,rgba(3,105,161,.14),transparent 68%)}\n.uv-hero-media img{position:relative;width:100%;border-radius:1.2rem;box-shadow:var(--shadow);z-index:1;border:1px solid var(--line)}\n.uv-announcement{background:#075985;color:#fff;padding:1rem 0}\n.uv-announcement .bta-uvo-wrap{display:flex;justify-content:center;align-items:center;gap:1rem;flex-wrap:wrap;text-align:center}\n.uv-announcement strong{font-size:1.05rem}\n.uv-badge{display:inline-block;border-radius:999px;padding:.35rem .8rem;font-family:\"MBF-Humanica\",\"Arial Black\",Impact,sans-serif;font-size:.7rem;letter-spacing:.12em;text-transform:uppercase;font-weight:bold}\n.uv-badge--copper{background:#78350f;color:#fff}\n.uv-badge--violet{background:#4C1D95;color:#fff}\n.uv-trust{padding:1.6rem 0 .5rem}\n.uv-trust-row{display:flex;flex-wrap:wrap;gap:.6rem}\n.uv-trust-item{background:#FFFFFF;border:1px solid var(--line);border-radius:8px;padding:.55rem .8rem;font-size:.85rem;color:#1a2e24}\n.uv-trust-item b{color:#075985;margin-right:.25rem}\n.uv-intro{padding:1rem 0 3.5rem}\n.uv-intro-box{background:#FFFFFF;border-left:4px solid #0369A1;border-radius:0 18px 18px 0;padding:clamp(1.4rem,4vw,2.5rem);box-shadow:var(--shadow);font-size:1.08rem}\n.uv-intro-box strong{color:#075985}\n.uv-section{padding:clamp(4rem,8vw,7rem) 0}\n.uv-section--panel{background:#E2F1EA}\n.uv-section--deep{background:#123326;color:#fff}\n.uv-section--deep h2,.uv-section--deep h3,.uv-section--deep h4{color:#fff}\n.uv-label{display:flex;align-items:center;gap:.75rem;color:#0369A1;font-family:\"MBF-Humanica\",\"Arial Black\",Impact,sans-serif;font-size:.72rem;letter-spacing:.3em;text-transform:uppercase;font-weight:bold;margin-bottom:.8rem}\n.uv-label:after{content:\"\";height:1px;width:5rem;background:#0369A1;opacity:.45}\n.uv-section-title{margin-bottom:.8rem}\n.uv-section-title span{color:#0369A1}\n.uv-card-grid{display:grid;grid-template-columns:repeat(3,minmax(0,1fr));gap:1rem;margin-top:2rem}\n.uv-card{background:#FFFFFF;border:1px solid var(--line);border-radius:18px;padding:1.5rem;box-shadow:0 8px 22px rgba(18,51,38,.06);transition:transform .25s ease,box-shadow .25s ease,border-color .25s ease}\n.uv-card:hover{transform:translateY(-4px);border-color:rgba(3,105,161,.35);box-shadow:var(--shadow)}\n.uv-card h3{color:#075985}\n.uv-card p,.uv-card li{color:#4a6b5c;font-size:.95rem}\n.uv-icon{font-size:2rem;margin-bottom:.7rem}\n.uv-table-scroll{overflow-x:auto;border-radius:18px;box-shadow:var(--shadow);margin-top:2rem}\n.uv-table{width:100%;min-width:900px;border-collapse:collapse;background:#FFFFFF;font-size:.92rem}\n.uv-table caption{text-align:left;padding:1rem;font-weight:bold;color:#123326;background:#D8ECDF}\n.uv-table th{background:#075985;color:#fff;text-align:left;padding:1rem;font-family:\"MBF-Humanica\",\"Arial Black\",Impact,sans-serif;font-size:.78rem;letter-spacing:.1em;text-transform:uppercase}\n.uv-table td{padding:1rem;border-bottom:1px solid var(--line);color:#1a2e24;vertical-align:top}\n.uv-table tr:last-child td{border-bottom:none}\n.uv-table tr:nth-child(even){background:#f6fbf8}\n.uv-table strong{color:#075985}\n.uv-option-grid{display:grid;grid-template-columns:repeat(4,minmax(0,1fr));gap:1rem;margin-top:2rem}\n.uv-option{background:#FFFFFF;border:1px solid var(--line);border-radius:14px;padding:1.25rem}\n.uv-option h3{font-size:1.05rem;color:#4C1D95}\n.uv-option p{font-size:.9rem;color:#4a6b5c;margin:0}\n.uv-crosssell{display:grid;grid-template-columns:1fr 1fr;gap:1rem;margin-top:2rem}\n.uv-crosssell-card{background:#FFFFFF;border:1px solid var(--line);border-radius:18px;padding:1.5rem}\n.uv-crosssell-card h3{color:#075985}\n.uv-crosssell-card p{color:#4a6b5c}\n.uv-link{font-weight:bold}\n.uv-included{display:grid;grid-template-columns:repeat(3,minmax(0,1fr));gap:1rem;margin-top:2rem}\n.uv-included .uv-card{border-top:4px solid #B45309}\n.uv-upgrade{display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:1rem;margin-top:2rem}\n.uv-upgrade .uv-card{border-top:4px solid #7C3AED}\n.uv-details{border-bottom:1px solid rgba(255,255,255,.2);padding:1rem 0}\n.uv-details summary{cursor:pointer;color:#fff;font-weight:bold;padding:.25rem 0}\n.uv-details p{color:#D7E9E0;margin:.75rem 0 0;padding-left:1.4rem}\n.uv-cta{text-align:center;background:#FFFFFF;border:1px solid var(--line);border-radius:18px;padding:2rem;max-width:44rem;margin:0 auto;box-shadow:var(--shadow)}\n.uv-cta p{color:#4a6b5c}\n.uv-button{display:inline-block;background:#78350f;color:#fff!important;text-decoration:none!important;border-radius:7px;padding:.85rem 1.2rem;font-family:\"MBF-Humanica\",\"Arial Black\",Impact,sans-serif;font-size:.82rem;letter-spacing:.1em;text-transform:uppercase;font-weight:bold;margin:.35rem;transition:background .2s ease,transform .2s ease,box-shadow .2s ease}\n.uv-button:hover{background:#5f270b;color:#fff!important;transform:translateY(-2px);box-shadow:0 8px 20px rgba(120,53,15,.25)}\n.uv-button--ocean{background:#075985}\n.uv-button--ocean:hover{background:#06466a}\n.uv-trade{text-align:center;background:#123326;color:#fff;padding:clamp(4rem,8vw,7rem) 0}\n.uv-trade p{color:#D7E9E0;max-width:42rem;margin:0 auto 1.5rem}\n.uv-trade h2{color:#fff}\n.uv-trade h2 span{color:#BAE6FD}\n.uv-small{font-size:.84rem;color:#D7E9E0}\n@media(max-width:900px){.uv-card-grid{grid-template-columns:1fr 1fr}.uv-option-grid{grid-template-columns:1fr 1fr}.uv-included{grid-template-columns:1fr 1fr}}\n@media(max-width:700px){.uv-hero-grid,.uv-crosssell,.uv-upgrade{grid-template-columns:1fr}.uv-card-grid,.uv-option-grid,.uv-included{grid-template-columns:1fr}.uv-hero-media{min-height:auto}.uv-section{padding:4rem 0}}\n@media(prefers-reduced-motion:reduce){.bta-uvo-page *,.bta-uvo-page *::before,.bta-uvo-page *::after{animation-duration:.001ms!important;animation-iteration-count:1!important;scroll-behavior:auto!important;transition-duration:.001ms!important}.uv-card:hover,.uv-button:hover{transform:none}}\n\u003c\/style\u003e\n\n\u003cdiv class=\"bta-uvo-page\"\u003e\n\n\u003csection class=\"uv-hero\" aria-labelledby=\"uvo-title\"\u003e\n\u003cdiv class=\"bta-uvo-wrap uv-hero-grid\"\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"uv-kicker\"\u003eBTA commercial UV sterilisation\u003c\/div\u003e\n\u003ch1 id=\"uvo-title\"\u003eUVONIC \u003cspan\u003eCMLA\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp style=\"font-family:'MBF-Humanica','Arial Black',Impact,sans-serif;font-size:clamp(1rem,2.2vw,1.4rem);color:#0369A1;letter-spacing:.06em;margin:-0.5rem 0 1.5rem;text-transform:uppercase\"\u003eCommercial Multi-Lamp Amalgam UV Steriliser Series\u003c\/p\u003e\n\u003cp class=\"uv-lead\"\u003eEngineered multi-lamp amalgam UV reactors for aquaculture, RAS and commercial water treatment — powered by BTA's custom-built UV steriliser engineering software, bringing another level of accuracy to UV sizing.\u003c\/p\u003e\n\u003cdiv class=\"uv-stat-row\" aria-label=\"Key specifications\"\u003e\n\u003cdiv class=\"uv-stat\"\u003e\n\u003cstrong\u003e280 \u0026amp; 315\u003c\/strong\u003e\u003csmall\u003emm chambers\u003c\/small\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"uv-stat\"\u003e\n\u003cstrong\u003eUp to 10\u003c\/strong\u003e\u003csmall\u003eamalgam lamps\u003c\/small\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"uv-stat\"\u003e\n\u003cstrong\u003e320W\u003c\/strong\u003e\u003csmall\u003eper lamp steps\u003c\/small\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"uv-hero-media\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0731\/5200\/4338\/files\/UV_Calculator_1_42e6cbcb-3587-4973-b7b4-134ded7418ee.jpg?v=1790065261\" alt=\"BTA UV dose calculator title banner showing probe point count quadrature method compute time and accuracy statistics\" style=\"width:100%;border-radius:1.2rem;box-shadow:0 16px 44px rgba(18,51,38,.12);border:1px solid rgba(18,51,38,.14)\" loading=\"eager\" fetchpriority=\"high\" decoding=\"async\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"uv-announcement\" aria-label=\"Product highlights\"\u003e\n\u003cdiv class=\"bta-uvo-wrap\"\u003e\n\u003cspan class=\"uv-badge uv-badge--copper\"\u003eAmalgam lamp technology\u003c\/span\u003e\u003cstrong\u003eMulti-lamp · Vertical or horizontal · Custom inlet\/outlet sizes\u003c\/strong\u003e\u003cspan class=\"uv-badge uv-badge--violet\"\u003eMaterial-aware dose modelling\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"uv-trust\" aria-label=\"Product benefits\"\u003e\u003cdiv class=\"bta-uvo-wrap uv-trust-row\"\u003e\n\u003cspan class=\"uv-trust-item\"\u003e\u003cb aria-hidden=\"true\"\u003e✓\u003c\/b\u003e Amalgam lamps — stable output\u003c\/span\u003e\u003cspan class=\"uv-trust-item\"\u003e\u003cb aria-hidden=\"true\"\u003e✓\u003c\/b\u003e Individual ballast per lamp\u003c\/span\u003e\u003cspan class=\"uv-trust-item\"\u003e\u003cb aria-hidden=\"true\"\u003e✓\u003c\/b\u003e Over-temperature protection\u003c\/span\u003e\u003cspan class=\"uv-trust-item\"\u003e\u003cb aria-hidden=\"true\"\u003e✓\u003c\/b\u003e Custom dose-rate sizing\u003c\/span\u003e\n\u003c\/div\u003e\u003c\/section\u003e\n\n\u003csection class=\"uv-intro\"\u003e\u003cdiv class=\"bta-uvo-wrap\"\u003e\u003cdiv class=\"uv-intro-box\"\u003e\n\u003cstrong\u003eThe UVONIC CMLA — Commercial Multi-Lamp Amalgam Series — is engineered around one principle: every reactor is sized to your actual dose target.\u003c\/strong\u003e Most commercially available UV calculators only model stainless steel chambers. Ours models the real world — stainless, white PVC and dark chambers (grey PVC or black HDPE) all reflect and absorb 254 nm UV differently, and that changes the delivered dose. Our in-house MPSS dose engine — BTA's custom-built UV steriliser engineering software — places every lamp, models chamber material, water transmittance and geometry for your actual system. The software is as much a part of every UVONIC build as the reactors themselves.\u003c\/div\u003e\u003c\/div\u003e\u003c\/section\u003e\n\n\u003csection class=\"uv-section uv-section--panel\" aria-labelledby=\"difference-title\"\u003e\n\u003cdiv class=\"bta-uvo-wrap\"\u003e\n\u003cdiv class=\"uv-label\"\u003eThe UVONIC difference\u003c\/div\u003e\n\u003ch2 id=\"difference-title\" class=\"uv-section-title\"\u003eSized by modelling. \u003cspan\u003eNot by guesswork.\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cdiv class=\"uv-card-grid\"\u003e\n\u003carticle class=\"uv-card\"\u003e\u003cdiv class=\"uv-icon\" aria-hidden=\"true\"\u003e📐\u003c\/div\u003e\n\u003ch3\u003eTrue multi-lamp geometry\u003c\/h3\u003e\n\u003cp\u003eLamp placement changes everything in a multi-lamp reactor. Our engine models up to 10 lamps by exact X\/Y position, arc length and output — so dose is engineered, not assumed from a single-lamp chart.\u003c\/p\u003e\u003c\/article\u003e\n\u003carticle class=\"uv-card\"\u003e\u003cdiv class=\"uv-icon\" aria-hidden=\"true\"\u003e🧱\u003c\/div\u003e\n\u003ch3\u003eChamber material matters\u003c\/h3\u003e\n\u003cp\u003eStainless steel, white PVC and dark chambers (grey PVC or black HDPE) reflect 254 nm UV very differently. The calculator applies material-specific geometry factors so every build is sized honestly.\u003c\/p\u003e\u003c\/article\u003e\n\u003carticle class=\"uv-card\"\u003e\u003cdiv class=\"uv-icon\" aria-hidden=\"true\"\u003e🎯\u003c\/div\u003e\n\u003ch3\u003eSized to your system\u003c\/h3\u003e\n\u003cp\u003eEvery reactor is modelled lamp-by-lamp for your flow, water quality and target dose before it is built — so the dose you need is the dose you get.\u003c\/p\u003e\u003c\/article\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"uv-section\" aria-labelledby=\"engineering-title\"\u003e\n\u003cdiv class=\"bta-uvo-wrap\"\u003e\n\u003cdiv class=\"uv-label\"\u003eIn-house engineering\u003c\/div\u003e\n\u003ch2 id=\"engineering-title\" class=\"uv-section-title\"\u003eEvery reactor is \u003cspan\u003emodelled before it is built\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cdiv class=\"uv-card-grid\"\u003e\n\u003carticle class=\"uv-card\"\u003e\u003cdiv class=\"uv-icon\" aria-hidden=\"true\"\u003e🛠\u003c\/div\u003e\n\u003ch3\u003eReactor parameters\u003c\/h3\u003e\n\u003cp\u003eChamber dimensions, sleeve size, flow rate and water %T at 254 nm are entered for your system — not a generic worst case.\u003c\/p\u003e\u003c\/article\u003e\n\u003carticle class=\"uv-card\"\u003e\u003cdiv class=\"uv-icon\" aria-hidden=\"true\"\u003e💡\u003c\/div\u003e\n\u003ch3\u003eLamp-by-lamp layout\u003c\/h3\u003e\n\u003cp\u003eUp to 10 lamps placed by exact X\/Y position with individual wattage, arc length and efficiency — the layout that actually goes into your reactor.\u003c\/p\u003e\u003c\/article\u003e\n\u003carticle class=\"uv-card\"\u003e\u003cdiv class=\"uv-icon\" aria-hidden=\"true\"\u003e📊\u003c\/div\u003e\n\u003ch3\u003eDose you can check\u003c\/h3\u003e\n\u003cp\u003eNew-lamp dose, end-of-lamp-life dose and a 10% safety-factor design value are reported for every configuration.\u003c\/p\u003e\u003c\/article\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-top:.5rem;display:flex;flex-direction:column;gap:.9rem\"\u003e\n\u003cfigure style=\"margin:.9rem auto\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0731\/5200\/4338\/files\/UV_Calculator_2_-_chamber_material_4a405df0-eaae-452f-8967-253add1658d0.jpg?v=1790065261\" alt=\"Reactor parameters form including chamber material selector for stainless steel white PVC and dark grey PVC or black HDPE\" style=\"max-width:min(100%,720px);width:100%;height:auto;display:block;margin-left:auto;margin-right:auto;border-radius:18px;box-shadow:0 16px 44px rgba(18,51,38,.12);border:1px solid rgba(18,51,38,.14)\" loading=\"lazy\" decoding=\"async\"\u003e\u003cfigcaption style=\"text-align:center;color:#0369A1;font-size:.85rem;font-weight:bold;margin-top:.55rem\"\u003eWe size for your reactor material\u003c\/figcaption\u003e\u003c\/figure\u003e\u003cfigure style=\"margin:.9rem auto\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0731\/5200\/4338\/files\/UV_Calculator_3_xy_68297fbb-919a-4f45-9f4f-0a8def20da53.jpg?v=1790065261\" alt=\"Lamp positioning entered by exact X and Y coordinates inside reactor cross-section\" style=\"max-width:min(100%,720px);width:100%;height:auto;display:block;margin-left:auto;margin-right:auto;border-radius:18px;box-shadow:0 16px 44px rgba(18,51,38,.12);border:1px solid rgba(18,51,38,.14)\" loading=\"lazy\" decoding=\"async\"\u003e\u003cfigcaption style=\"text-align:center;color:#0369A1;font-size:.85rem;font-weight:bold;margin-top:.55rem\"\u003eCustomisable X\/Y positioning vs chamber diameter\u003c\/figcaption\u003e\u003c\/figure\u003e\u003cfigure style=\"margin:.9rem auto\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0731\/5200\/4338\/files\/UV_Calculator_5_a4d32edb-79a7-4ec2-85db-0074ae9f0d53.jpg?v=1790065261\" alt=\"Results panel showing residence time geometry factor corrected fluence and final dose values\" style=\"max-width:min(100%,720px);width:100%;height:auto;display:block;margin-left:auto;margin-right:auto;border-radius:18px;box-shadow:0 16px 44px rgba(18,51,38,.12);border:1px solid rgba(18,51,38,.14)\" loading=\"lazy\" decoding=\"async\"\u003e\u003cfigcaption style=\"text-align:center;color:#0369A1;font-size:.85rem;font-weight:bold;margin-top:.55rem\"\u003eUV results — T5 and Amalgam specific sizing\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"uv-section uv-section--panel\" aria-labelledby=\"map-title\"\u003e\n\u003cdiv class=\"bta-uvo-wrap\"\u003e\n\u003cdiv class=\"uv-label\"\u003eFluence distribution\u003c\/div\u003e\n\u003ch2 id=\"map-title\" class=\"uv-section-title\"\u003eSee the dose \u003cspan\u003ebefore you buy\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cfigure style=\"margin:.9rem auto\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0731\/5200\/4338\/files\/UV_Calculator_6_fluence_distribution_c02a912a-2fc1-45e1-aa6a-36ba8e77315d.jpg?v=1790065261\" alt=\"Cross-section fluence rate distribution contour plot of five-lamp reactor midplane\" style=\"max-width:min(100%,720px);width:100%;height:auto;display:block;margin-left:auto;margin-right:auto;border-radius:18px;box-shadow:0 16px 44px rgba(18,51,38,.12);border:1px solid rgba(18,51,38,.14)\" loading=\"lazy\" decoding=\"async\"\u003e\u003cfigcaption style=\"text-align:center;color:#0369A1;font-size:.85rem;font-weight:bold;margin-top:.55rem\"\u003eFluence distribution chart\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003cfigure style=\"margin:.9rem auto\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0731\/5200\/4338\/files\/UV_Calculator_1_42e6cbcb-3587-4973-b7b4-134ded7418ee.jpg?v=1790065261\" alt=\"BTA UV dose calculator title banner showing probe point count quadrature method compute time and accuracy statistics\" style=\"max-width:min(100%,720px);width:100%;height:auto;display:block;margin-left:auto;margin-right:auto;border-radius:18px;box-shadow:0 16px 44px rgba(18,51,38,.12);border:1px solid rgba(18,51,38,.14)\" loading=\"lazy\" decoding=\"async\"\u003e\u003cfigcaption style=\"text-align:center;color:#0369A1;font-size:.85rem;font-weight:bold;margin-top:.55rem\"\u003eBTA's custom-built UV steriliser engineering software — the engine behind every UVONIC CMLA build\u003c\/figcaption\u003e\u003c\/figure\u003e\n\n\u003csection class=\"uv-section\" aria-labelledby=\"spec-title\"\u003e\n\u003cdiv class=\"bta-uvo-wrap\"\u003e\n\u003cdiv class=\"uv-label\"\u003eSeries specifications\u003c\/div\u003e\n\u003ch2 id=\"spec-title\" class=\"uv-section-title\"\u003eThe numbers \u003cspan\u003ethat matter\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cdiv class=\"uv-table-scroll\"\u003e\n\u003ctable class=\"uv-table\"\u003e\n\u003ccaption\u003eUVONIC CMLA (Commercial Multi-Lamp Amalgam) specifications\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eProperty\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSpecification\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eNotes\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChamber series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e280 mm and 315 mm diameters\u003c\/td\u003e\n\u003ctd\u003eAll units 1750 mm long — custom lengths available.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e280 series dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330 mm wide × 480 mm high overall\u003c\/td\u003e\n\u003ctd\u003eHeight includes the UV lamp mounts.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e315 series dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e360 mm wide × 515 mm high overall\u003c\/td\u003e\n\u003ctd\u003eHeight includes the mounting frame.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLamp technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAmalgam UV lamps (254 nm)\u003c\/td\u003e\n\u003ctd\u003eStable output across a wide operating range.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLamp count\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 10 lamps per reactor\u003c\/td\u003e\n\u003ctd\u003eLayout engineered per application.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrientation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical or horizontal\u003c\/td\u003e\n\u003ctd\u003eBuilt to suit your plant layout.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInlet \/ outlet flanges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 mm, 100 mm, 150 mm or 200 mm\u003c\/td\u003e\n\u003ctd\u003eInterchangeable mounting options matched to your pipework.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChamber materials modelled\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStainless steel · White PVC · Dark (grey PVC or black HDPE)\u003c\/td\u003e\n\u003ctd\u003eDose sizing accounts for material reflectance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl box\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndividual ballast per lamp\u003c\/td\u003e\n\u003ctd\u003eVoltage meter, on\/off meter, bulb indicator lights, over-temperature sensor.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptional extras\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow meters with low\/high transducer switches\u003c\/td\u003e\n\u003ctd\u003eBackup protection for the over-temperature sensor.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCustom dose rates\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSized to your target UV dose\u003c\/td\u003e\n\u003ctd\u003eTell us your flow, %T and target dose — we engineer the reactor.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"uv-table-scroll\"\u003e\u003ctable class=\"uv-table\"\u003e\n\u003ccaption\u003eUVONIC CMLA model range by chamber diameter and total wattage\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eLamps\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eTotal wattage\u003c\/th\u003e\n\u003cth scope=\"col\"\u003e280 mm chamber\u003c\/th\u003e\n\u003cth scope=\"col\"\u003e315 mm chamber\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e320 W\u003c\/td\u003e\n\u003ctd\u003eUV-CMLA-280-320\u003c\/td\u003e\n\u003ctd\u003eUV-CMLA-315-320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e640 W\u003c\/td\u003e\n\u003ctd\u003eUV-CMLA-280-640\u003c\/td\u003e\n\u003ctd\u003eUV-CMLA-315-640\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e960 W\u003c\/td\u003e\n\u003ctd\u003eUV-CMLA-280-960\u003c\/td\u003e\n\u003ctd\u003eUV-CMLA-315-960\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e1,280 W\u003c\/td\u003e\n\u003ctd\u003eUV-CMLA-280-1280\u003c\/td\u003e\n\u003ctd\u003eUV-CMLA-315-1280\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e1,600 W\u003c\/td\u003e\n\u003ctd\u003eUV-CMLA-280-1600\u003c\/td\u003e\n\u003ctd\u003eUV-CMLA-315-1600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e1,920 W\u003c\/td\u003e\n\u003ctd\u003eUV-CMLA-280-1920\u003c\/td\u003e\n\u003ctd\u003eUV-CMLA-315-1920\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003e2,240 W\u003c\/td\u003e\n\u003ctd\u003eUV-CMLA-280-2240\u003c\/td\u003e\n\u003ctd\u003eUV-CMLA-315-2240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e2,560 W\u003c\/td\u003e\n\u003ctd\u003eUV-CMLA-280-2560\u003c\/td\u003e\n\u003ctd\u003eUV-CMLA-315-2560\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003ctd\u003e2,880 W\u003c\/td\u003e\n\u003ctd\u003eUV-CMLA-280-2880\u003c\/td\u003e\n\u003ctd\u003eUV-CMLA-315-2880\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e3,200 W\u003c\/td\u003e\n\u003ctd\u003eUV-CMLA-280-3200\u003c\/td\u003e\n\u003ctd\u003eUV-CMLA-315-3200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\n\n\n\u003csection class=\"uv-section uv-section--panel\" aria-labelledby=\"options-title\"\u003e\n\u003cdiv class=\"bta-uvo-wrap\"\u003e\n\u003cdiv class=\"uv-label\"\u003eConfiguration options\u003c\/div\u003e\n\u003ch2 id=\"options-title\" class=\"uv-section-title\"\u003eBuilt to \u003cspan\u003eyour plant\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cdiv class=\"uv-option-grid\"\u003e\n\u003carticle class=\"uv-option\"\u003e\u003ch3\u003eVertical or horizontal\u003c\/h3\u003e\n\u003cp\u003eChamber orientation built to suit your space and pipework runs.\u003c\/p\u003e\u003c\/article\u003e\n\u003carticle class=\"uv-option\"\u003e\u003ch3\u003eInterchangeable connections\u003c\/h3\u003e\n\u003cp\u003eInlet and outlet sizes are customisable and interchangeable to match your pipework.\u003c\/p\u003e\u003c\/article\u003e\n\u003carticle class=\"uv-option\"\u003e\u003ch3\u003eCustom dose rates\u003c\/h3\u003e\n\u003cp\u003eSized to your target UV dose rate for your flow and water transmittance.\u003c\/p\u003e\u003c\/article\u003e\n\u003carticle class=\"uv-option\"\u003e\u003ch3\u003eFlow meter option\u003c\/h3\u003e\n\u003cp\u003eFlow meters with low\/high transducer switches available as a backup to over-temperature protection.\u003c\/p\u003e\u003c\/article\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"uv-section\" aria-labelledby=\"crosssell-title\"\u003e\n\u003cdiv class=\"bta-uvo-wrap\"\u003e\n\u003cdiv class=\"uv-label\"\u003eRelated equipment\u003c\/div\u003e\n\u003ch2 id=\"crosssell-title\" class=\"uv-section-title\"\u003eComplete the \u003cspan\u003etreatment train\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cdiv class=\"uv-crosssell\"\u003e\n\u003carticle class=\"uv-crosssell-card\"\u003e\u003ch3\u003eProtein skimmers \u0026amp; foam fractionation\u003c\/h3\u003e\n\u003cp\u003eRemove fine solids and dissolved organics before UV treatment for better transmittance and dose delivery.\u003c\/p\u003e\n\u003ca class=\"uv-link\" href=\"\/collections\/protein-skimmers\"\u003eView skimmers\u003c\/a\u003e\u003c\/article\u003e\n\u003carticle class=\"uv-crosssell-card\"\u003e\u003ch3\u003eNot sure what you need?\u003c\/h3\u003e\n\u003cp\u003eSend BTA your flow rate, water %T and target dose — we will size the full treatment train, not just the reactor.\u003c\/p\u003e\n\u003ca class=\"uv-link\" href=\"\/pages\/contact\"\u003eContact BTA\u003c\/a\u003e\u003c\/article\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"uv-section uv-section--panel\" aria-labelledby=\"included-title\"\u003e\n\u003cdiv class=\"bta-uvo-wrap\"\u003e\n\u003cdiv class=\"uv-label\"\u003eWhat's included\u003c\/div\u003e\n\u003ch2 id=\"included-title\" class=\"uv-section-title\"\u003eEvery unit \u003cspan\u003eships complete\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cdiv class=\"uv-included\"\u003e\n\u003carticle class=\"uv-card\"\u003e\u003ch3\u003eUV reactor chamber\u003c\/h3\u003e\n\u003cp\u003e280 mm or 315 mm multi-lamp amalgam chamber in your chosen orientation with customisable inlet\/outlet connections.\u003c\/p\u003e\u003c\/article\u003e\n\u003carticle class=\"uv-card\"\u003e\u003ch3\u003eCentral control box\u003c\/h3\u003e\n\u003cp\u003eVoltage meter, on\/off meter, bulb indicator lights and over-temperature sensor — each lamp driven by its own individual ballast.\u003c\/p\u003e\u003c\/article\u003e\n\u003carticle class=\"uv-card\"\u003e\u003ch3\u003eDose sizing report\u003c\/h3\u003e\n\u003cp\u003eYour reactor's modelled dose: new-lamp output, end-of-lamp-life value and 10% safety-factor design figure.\u003c\/p\u003e\u003c\/article\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"uv-section\" aria-labelledby=\"upgrade-title\"\u003e\n\u003cdiv class=\"bta-uvo-wrap\"\u003e\n\u003cdiv class=\"uv-label\"\u003eDesign philosophy\u003c\/div\u003e\n\u003ch2 id=\"upgrade-title\" class=\"uv-section-title\"\u003eWhy no LCD screen or \u003cspan\u003eUV intensity sensor?\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cdiv class=\"uv-upgrade\"\u003e\n\u003carticle class=\"uv-card\"\u003e\u003ch3\u003eNo LCD screen\u003c\/h3\u003e\n\u003cp\u003eLCD displays add significant cost to commercial UV control boxes without adding treatment value. The UVONIC control box carries the meters that actually matter: voltage, on\/off status, per-lamp bulb indicators and over-temperature sensing.\u003c\/p\u003e\u003c\/article\u003e\n\u003carticle class=\"uv-card\"\u003e\u003ch3\u003eNo UV intensity sensor\u003c\/h3\u003e\n\u003cp\u003eIn a multi-lamp reactor a single intensity sensor cannot read the chamber accurately — if a lamp on the far side of the reactor fails, a spot sensor still shows healthy output. Every UVONIC unit is instead sized to the target dose with end-of-lamp-life factors built into the design.\u003c\/p\u003e\u003c\/article\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"uv-section uv-section--deep\" aria-labelledby=\"faq-title\"\u003e\n\u003cdiv class=\"bta-uvo-wrap\"\u003e\n\u003cdiv class=\"uv-label\"\u003eFrequently asked questions\u003c\/div\u003e\n\u003ch2 id=\"faq-title\" class=\"uv-section-title\"\u003eUVONIC \u003cspan\u003eFAQs\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cdetails class=\"uv-details\"\u003e\u003csummary\u003eWhat chamber sizes are available?\u003c\/summary\u003e\u003cp\u003eThe current range covers 280 mm and 315 mm chambers, with more sizes in development. Custom configurations are available on request.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails class=\"uv-details\"\u003e\u003csummary\u003eCan the reactor be mounted vertically or horizontally?\u003c\/summary\u003e\u003cp\u003eYes. UVONIC reactors are built to any format — vertical or horizontal — with interchangeable inlet and outlet connections in customisable sizes to suit your pipework.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails class=\"uv-details\"\u003e\u003csummary\u003eDoes chamber material really change the UV dose?\u003c\/summary\u003e\u003cp\u003eYes. Stainless steel, white PVC and dark chambers (grey PVC or black HDPE) reflect 254 nm UV differently, which changes the delivered dose. Our dose calculator applies material-specific geometry factors so every build is sized honestly for its actual chamber material.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails class=\"uv-details\"\u003e\u003csummary\u003eHow do you size the reactor to my system?\u003c\/summary\u003e\u003cp\u003eWe model every reactor lamp-by-lamp with our custom-built UV engineering software using your flow rate, water transmittance, chamber material and target dose — so the unit you receive is sized to the dose your system actually needs.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails class=\"uv-details\"\u003e\u003csummary\u003eWhy doesn't the control box have an LCD screen or UV sensor?\u003c\/summary\u003e\u003cp\u003eLCD screens add substantial cost without treatment benefit, and in a multi-lamp reactor a single UV intensity sensor cannot accurately measure chamber output — especially if a lamp on the opposite side fails. Instead, each lamp has its own ballast and indicator light, and every unit is sized to its target dose rate with end-of-lamp-life factors included.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails class=\"uv-details\"\u003e\u003csummary\u003eCan I get flow monitoring?\u003c\/summary\u003e\u003cp\u003eYes. Flow meters with low and high transducer switches are available as an option — they also serve as a backup to the over-temperature sensor included as standard.\u003c\/p\u003e\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"uv-section\" aria-labelledby=\"help-title\"\u003e\n\u003cdiv class=\"bta-uvo-wrap\"\u003e\n\u003cdiv class=\"uv-cta\"\u003e\n\u003ch2 id=\"help-title\"\u003eNot sure what your UV is actually doing?\u003c\/h2\u003e\n\u003cp\u003eWant to check the sizing of an existing unit, or retrofit a UV reactor to another system and verify the dose rate? That is exactly what we built our UV calculator for. Send us your flow rate, water transmittance and target dose — we will model it and give you the numbers.\u003c\/p\u003e\n\u003ca class=\"uv-button uv-button--ocean\" href=\"\/pages\/contact\"\u003eTalk to BTA\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"uv-trade\" aria-labelledby=\"trade-title\"\u003e\n\u003cdiv class=\"bta-uvo-wrap\"\u003e\n\u003ch2 id=\"trade-title\"\u003eTrade \u003cspan\u003e\u0026amp; wholesale\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp\u003eAquaculture facilities, RAS operators, maintenance teams and installers can contact BTA for commercial UV sizing, bulk requirements and trade pricing.\u003c\/p\u003e\n\u003ca class=\"uv-button\" href=\"\/pages\/contact\"\u003eRequest trade pricing\u003c\/a\u003e\n\u003ca class=\"uv-button uv-button--ocean\" href=\"\/pages\/contact\"\u003eAsk a technical question\u003c\/a\u003e\n\u003cp class=\"uv-small\"\u003eBiotech Aquatica · Australian supplier · btaqua.com.au\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n\"@context\":\"https:\/\/schema.org\",\n\"@type\":\"Product\",\n\"name\":\"UVONIC CMLA Commercial Multi-Lamp Amalgam UV Steriliser\",\n\"description\":\"Multi-lamp amalgam UV steriliser reactors for aquaculture and commercial water treatment. 280 mm and 315 mm chambers, up to 10 amalgam lamps, vertical or horizontal orientation with customisable inlet and outlet sizes. Sized with BTA custom-built UV engineering software.\",\n\"brand\":{\"@type\":\"Brand\",\"name\":\"Biotech Aquatica\"},\n\"category\":\"Commercial UV Sterilisers\",\n\"material\":\"Stainless Steel \/ White PVC \/ Dark (grey PVC or black HDPE) chamber options\"\n}\n\u003c\/script\u003e\n","brand":"Biotech Aquatica ","offers":[{"title":"640 watt 280 series 2 x 320 watt UVonic CMLA Commercial Amalgam UV with control box","offer_id":50514356175090,"sku":null,"price":24150.0,"currency_code":"AUD","in_stock":true},{"title":"1280 watt 280 series 4 x 320 watt UVonic CMLA Commercial Amalgam UV with control box","offer_id":50514356207858,"sku":null,"price":31795.0,"currency_code":"AUD","in_stock":true},{"title":"1600 watt 315 series 5 x 320 watt UVonic CMLA Commercial Amalgam UV with control box","offer_id":50514356240626,"sku":null,"price":40697.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0731\/5200\/4338\/files\/commercialUV2.png?v=1790059717","url":"https:\/\/www.btaqua.com.au\/products\/uvonic-cmla-multi-lamp-amalgam-uv-steriliser","provider":"Biotech Aquatica ","version":"1.0","type":"link"}